5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically or horizontally to each side of 2” x 3” or 2” x 4” wood studs, turned flatwise 24” (610 mm) o.c. 25 MSG galv steel, attached to floor and ceiling with fasteners spaced 24 in. (3) • Protection of combustible insulation and foam plastic insulation per Articles 3.1.5.14 and 3.1.5.14. at top and bottom track, 16” (406 mm) o.c. Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C gypsum wallboard or DensArmor Plus® Fireguard C panels each side of assembly and 3-1/2” (89 mm) fiberglass insulation in stud space both sides. Horizontal edge joints and horizontal butt joints on opposite side of studs need not be staggered. Joint compound 1/16” (2.0 mm) thick applied over corner bead. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied horizontally to studs with 2-1/2″ Type W Screws 8” (203 mm) o.c. suspended from the upper channels with 1/2” (12.7 mm) Type S pan-head screws and supported steel channels installed at lower corners of brackets. Joints staggered. ZC�HP and not less than 1” (25 mm) apart with 1” (25 mm) Type S drywall screws 8” (203 mm) o.c. Base Layer: 1/4” (6.4 mm) ToughRock® gypsum board applied vertically to each side of 1-5/8” (41 mm) 25 gauge (18 mils) steel studs 24” (610 mm) o.c. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus Fireguard applied perpendicular to joists with 1-7/8” (48 mm) Type S-12 drywall screws 12” (305 mm) o.c. ), 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panel applied perpendicular to rigid resilient channels 24” (610 mm) o.c. 1-1/4” (32 mm) steel beads at corners attached with 6d coated nails 1-3/4” (45 mm) long, 0.0915” (2 mm) shank, 1/4” (6 mm) heads, 12” (305 mm) o.c. with 1” (25 mm) Type S drywall screws 36” (914 mm) o.c. Joints staggered 24” (610 mm) each layer and side. for base layer and 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. Designed for ceiling or duct shaft and composed of 1” (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel supported by 2-1/2” (64 mm), 4” (102 mm) or 6” (152 mm) C-T studs and three layers of 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum board. (124, 156, 187 and 219 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m 3) structural concrete for 1, 2, 3 and 4 Hr rated assemblies, respectively. All design details enhancing the structural integrity of the wall assembly, including the axial design load of the studs, shall be as specified by the steel stud designer and/or producer, and shall meet the requirements of all applicable local code agencies. Any thickness polyisocyanurate foamed plastic; polystyrene foamed plastic; or mineral fiber or glass fiber insulation boards laid over gypsum sheathing and covered by a Class A, B or C roof covering. Face layer attached with 1-5/8” (41 mm) Type S-12 bugle head screws spaced 12” (305 mm) o.c. Stagger joints 24” (610 mm) each layer and side. Steel Studs — Systems A, B, E, G and I at edges and top and bottom runners, 12” (305 mm) o.c. spacing of wall assemblies shall not exceed 24 in. (NLB). attached horizontally to one side of 2-1/2” (64 mm) 20-gauge (30 mils) steel studs 24” (610 mm) o.c. Sometimes it is necessary to introduce batt insulation into these in order to reduce sound and/or thermal transmission. Base Layer: 5/8” (15.9 mm) ToughRock® Fireguard X™ Products or 5/8” (15.9 mm) DensArmor Plus® Fireguard® applied vertically or horizontally to each side of 2” x 3” or 2” x 4” wood studs, turned flatwise 24” (610 mm) o.c. Drywall end joints located midway between continuous channels and attached to additional pieces of channel 60” (1524 mm) long with 1” (25 mm) Type S screws 8” (203 mm) o.c. with 1-3/4” (45 mm) galvanized roofing nails 7” (178 mm) o.c. See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances Design No. on 2” x 6” wood plates with 1-7/8” (48 mm) 6d coated nails 7” (178 mm) o.c. Exterior Wall Assembly Tested . Sound Tested with 3-1/2” (89 mm) fiberglass insulation, friction fit in 3-5/8” (92 mm) stud space. Batt or blanket insulation optional. Four layers of 5/8” (15.9 mm) ToughRock® Fireguard C® gypsum board or 5/8” (15.9 mm) DensArmor Plus® Fireguard C® covering W10 x 49 (metric W250 x 73) steel column. 3-1/2” (89 mm) corrosion resistant 20-gauge (30 mils) steel studs 24” (610 mm) o.c. Resilient channels 24” o.c. Please contact the manufacturer of such products for installation instructions. Concrete Blocks of Various Designs — (CAZTC). OC. Resilient channel 24” (610 mm) o.c. Resilient channels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. 24″ (610 mm) with 1-1/4″ Type S or W screws. at intermediate studs. �)4�Ь�YC�Ff.��_j }�a�d� �&�0A� 2L�a��-4�_٩��Ȥ���]:'W� l.
Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to one side with 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. Belgium. Albania. long angles with one nom 4 in. (Load Bearing: 80% of design load), Base Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® (per UL V487 only) or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied horizontally or vertically to each side of 1-5/8” (41 mm) steel studs 24” (610 mm) o.c. Three layers of 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels around minimum W8 x 24 (metric W200 x 36) beam. with 2” (51 mm) 6d coated nails. to open web steel joists 24” (610 mm) o.c. Joints staggered. 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panel applied perpendicular to resilient channels 24” (610 mm) o.c. at joints and floor and ceiling runners and 12” (305 mm) o.c. Face layer 5/8″ (15.9 mm) ToughRock® Fireguard X® Products or 5/8″ (15.9 mm) DensArmor Plus® Fireguard® gypsum panels installed vertically to studs with 1-58″ Type S screws 24″ o.c. Horizontal joints staggered not less than 6” (152 mm) between layers. Click this link to go to EMSEAL’s Index on the UL Online Certifications Directory. 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically or horizontally to each side of 2” x 4” wood studs 16” (406 mm) o.c. Face layer attached with 1-5/8” (41 mm) Type S corrosion resistant bugle head screws spaced 8” (203 mm) o.c. 8 x 1/2” (13 mm) self-drilling steel screws at each end. Opposite Side Base Layer: 1/2” (12.7 mm) ToughRock Fireguard C or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied horizontally to studs with 1” (25 mm) Type S drywall screws 24” (610 mm) o.c. Screws spaced 3” (76 mm) from the stud joints. UL and ULC Classified. Horizontal joints need not be backed by framing. Interior Base Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically or horizontally to 2”x 4” wood studs 16” (406 mm) o.c. Face Layer: 5/8” (15.9 mm) ToughRock Fireguard C gypsum board or 5/8” (15.9 mm) DensArmor Plus Fireguard C gypsum panels applied perpendicular to channels with 1-5/8” (41 mm) Type S drywall screws, 8” (203 mm) o.c. placed 2″ back on either side of vertical joints. Consult each listing for specific information. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied perpendicular to joists through base layer with 1-7/8” (48 mm) Type W or S screws 12” (305 mm) o.c. Where total cavity depth exceeds 9-1/2” (241 mm), cross braces shall be fabricated with 25-gauge (18 mils) stud or runner pieces. UL/ULC Listings EMSHIELD Fire-Rated Expansion Joint UL/ULC Listing Index: The links in the following table connect to the actual UL Listing on the UL database. The ROCKWOOL Safe Use Instruction Sheet (SUIS) is provided to communicate safe handling and use instructions. Nonbearing Wall Ratings) - Proprietary channel shaped studs, 3-5/8 in. Joints staggered. Joint compound 1/16” (1.6 mm) thick applied over corner bead and entire outer layer of drywall. Install 2-1/2” (64 mm) Type S drywall screws 12” (305 mm) o.c. Report OL05-1046.pdf. UL is a global independent safety science company with more than a century of expertise innovating safety solutions. ULC W301 allows vertical application only. Managing moisture in wall assemblies Depending on your building codes and geographic location, a vapor barrier may be required when insulating exterior wall cavities. Wallboard nailed to top and bottom plates 7” (178 mm) o.c. Second Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panel applied vertically to each side with joints staggered 24” (610 mm) each side attached to studs with 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. The reduced wall clearances are specified as a with 18-gauge (43 mils) wire 15” (381 mm) o.c. UL Standards. Face Layer: Attached with 2-1/4” (57 mm) Type S drywall screws 5/8” (15.9 mm) o.c. Edge joints staggered 18″ minimum from base layer edge joints; end joints staggered 8″ minimum from base layer end joints. Fire data has been compiled from the following five sources: Underwriters’ Laboratories of Canada ULC 7 Underwriters Road Toronto, Ontario, Canada M1R 3B4 www.ulc.ca Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Joints staggered. and 1-1/2” (38 mm) Type G drywall screws 12” (305 mm) o.c. with 6d coated nails, 1-7/8” (48 mm) long, 0.0915” (2 mm) shank, 1/4” (6 mm) heads, 12” (305 mm) o.c. (NLB) Sound tested with 1-1/2″ glass fiber insulation friction fit in stud space. All wall assemblies are considered non load bearing unless otherwise speci˛ed. Interior: 5/8” (15.9 mm) DensArmor Plus® Fireguard® or 5/8” (15.9 mm) ToughRock® Fireguard X® applied vertically to framing with 1” (25 mm) Type S bugle head screws 8” (203 mm) o.c. Face Layer: 5/8” (15.9 mm) ToughRock Fireguard X Products or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied perpendicular to resilient channels through base layer with 1-7/8” (48 mm) Type S screws 8″ o.c. CAN/ULC S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials Meets 10 minute stay-in-place requirements CAN/ULC S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies Flame spread rating- 30 Smoke developed classification- 235 CAN/ULC S134 Standard Method of Fire Test of Exterior Wall Assemblies Assembly … Consult listed ˛re references for speci˛c gypsum board type and brand to obtain listed performance. Face layer 5/8″ (15.9 mm) ToughRock® Fireguard C® gypsum board or 5/8″ (15.9 mm) DensArmor Plus® Fireguard C® gypsum panels applied parallel to studs with 2-1/4″ Type S screws 12″ o.c. between studs 1-1/2” (38 mm) from joints. Face layer offset 24″ from base layer joints. at edge joints and intermediate framing. 2. Stagger joints 16” (406 mm) o.c. Base Layer: 1/2” (12.7 mm) ToughRock® Fireguard C® gypsum board tied to W10 x 49 (metric W250 x 73) column 1 hr. S tuds attached to floor and ceiling runners with 1/2 in. Outboard insulation included in assembly : Trespa Meteon Kraft FR . Resilient channels wire tied 24” (610 mm) o.c. When gypsum panels are other than 48” (1219 mm) wide, panels are applied horizontally to the framing. Discuss the difference in exterior walls, fire walls, fire barriers, and fire partitions, considering performance expectations, code requirements, and appropriate application. In fire-resistance-rated construction, building codes specify that floor/ceiling, roof/ceiling, and wall assemblies be rated using a standard fire-resistance test. Exterior: Base layer 5/8” (15.9 mm) DensGlass® Fireguard® Sheathing retardant treated 2 x 6 wood studs 16” (406 mm) o.c. Face Layer: 1/2” (12.7 mm) ToughRock Fireguard C or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied vertically to each side with 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. in each flange. Sound tested with 3-1/2” fiberglass insulation NLB. Horizontal edge joints and horizontal butt joints on opposite side of studs need not be staggered. E@�0`�S%�G��$F) Lc�± �I�c\�O�ծ��Hnf����܋Ҿd^��KQ!D��%'�����4��qU��m�G�g,�)]ۏ%���m�+ߘ��{grgV��u�_��(Ʊ� �9�=�Q��F+�Ӓ�i�]]��c�Vu�]�5R at intermediate studs. with 1” (25 mm) Type S screws 12” (305 mm) o.c. 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied perpendicular to resilient channels 24” (610 mm) o.c. Browse & Buy UL Standards. OC. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically to each side with 1-5/8” (41 mm) Type S-12 drywall screws 12” (305 mm) o.c. with 1” (25 mm) Type S drywall screws 24” (610 mm) o.c. Complete List of UL Documents; View Top Sellers; What's New; Request a Quote; UL Certification Customer Information. with 1” (25 mm) corrosion resistant bugle head screws 8” (203 mm) o.c. Joints offset 24” (610 mm) from base layer joints. 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to studs with 1” (25 mm) Type S drywall screws 8” (203 mm) o.c. Horizontal joints need not be backed by steel framing. ULC W301 allows vertical application only. The purpose of this guide is to amalgamate fire and sound data for steel floor and wall assemblies that are relevant to residential and light commercial construction. Steel Stud Partitions (Non-Load-Bearing) 61 STC* 2-hr. Austria. Understand the paths to achieving code compliant, fire-resistance rated wood frame assemblies as outlined by the 2015 IBC. Sound tested with 2-1/2” (64 mm) fiberglass insulation. Joint systems. Sentence 2 on a Genyk wall assembly containing Boreal Nature Type 2 spray applied polyurethane foam insulation with cement board and stucco finish. Steel cornerbead, 1-1/2” (38 mm) flanges, applied with 1” (25 mm) Type S drywall screws 12” (305 mm) o.c. Resilient channels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. Face Layer: 1/2” (12.7 mm) ToughRock Fireguard C or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied horizontally to framing with 1-5/8″ (41mm) Type S drywall screws 8″ (203mm) o.c. each layer and side. Load bearing. each layer and side or minimum 12″ when filler strip is used. Opposite side: Base layer 5/8″ (15.9 mm) ToughRock® Fireguard C® gypsum board or 5/8″ (15.9 mm) DensArmor Plus® Fireguard C® gypsum panels applied at right angles to studs with 1″ Type S screws 24″ o.c. Face Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panel applied vertically or horizontally to each side with 2-1/4” (57 mm) Type S drywall screws 12” (305 mm) o.c. with 1” (25 mm) Type S corrosion resistant bugle head screws 8” (203 mm) o.c. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard® gypsum board applied vertically to each side. when applied horizontally to studs and 8” (203 mm) at vertical and bottom edges and 12” (305 mm) o.c. Detail No. at intermediate studs. Sound Tested with 3-1/2” (89 mm) fiberglass insulation in joist spaces and with carpet and pad (2nd layer of drywall needed with insulation). UL Certification Customers may access published Standards materials by using the Standards … Wood joists supporting 1” (25.4 mm) nominal wood subfloor and 1” (25.4 mm) nominal wood finish floor, or 19/32” (15.1 mm) plywood finished floor with long edges T&G and 15/32” (11.9 mm) interior plywood with exterior glue subfloor perpendicular to joist with joints staggered. Trusses: Chord and web members fabricated from 2” x 4” lumber with 20-gauge (30 mils) steel connector plates having a minimum tooth length of 5/16” (7.9 mm). U428 October 13, 2015 Nonbearing Wall Rating — 2 Hr Combustible Exterior Wall Assembly in Buildings Required to be of Non-Combustible Construction • Building Code Requirements • Grenfell Tower Fire in Context • Overview of CAN/ULC-S134-92 – Fire Test of Exterior Wall Assemblies (S134) • Market Trends in Exterior Wall Design • Drawing and Site Review under the CP program Conversely, 3.1.5.12. addresses the protection of combustible insulation within the wall, or used as an interior finish, from interior fire spread. Second Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum panel or 1/2” (12.7 mm) DensArmor Plus Fireguard C applied vertically to each side with 1-5/8” (41 mm) Type S drywall screws 24” (610 mm) o.c. Fire data has been compiled from the following six sources: Underwriters Laboratories of Canada ULC 7 Underwriters Road Toronto, Ontario, Canada M1R 3B4 www.ulc.ca Base layer attached with 1” (25 mm) Type S corrosion resistant bugle head screws 16” (406 mm) o.c. staggered 8” (203 mm) o.c. Screws spaced 1/2” (12.7 mm) and 6” (152 mm) from side joints and 12” (305 mm) o.c. at intermediate studs when applied vertically to framing, or 8” (203 mm) o.c. Stagger joints each side. Load Bearing. maximum, with 1-5/8” (41 mm) Type S drywall screws, 8” (203 mm) o.c. Wood joist supporting 1/2” (12.7 mm) plywood with exterior glue applied perpendicular to top of joists with 8d nails. Third Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C® applied vertically to each side with 2-1/4” (57 mm) Type S drywall screws 24” (610 mm) o.c. fire- and sound-rated wall and ceiling assemblies utilizing THERMAFIBER Sound Attenuation Fire Blankets, contact Thermafiber, Inc. For further information about any of the assemblies listed here, consult your Thermafiber sales representative, or visit us online at www.thermafiber.com. Horizontal edge joints and horizontal butt joints in adjacent layers staggered a min of 12” (305 mm), Base Layer: 1/2” (12.7 mm) ToughRock Fireguard C or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum board applied vertically to each side of 2-1/2” (64 mm) steel studs 24” (610 mm) o.c. ... Report OL05-1046.pdf. Gypsum panels end joints located midway between continuous channels and attached to additional pieces of channels 60” (1524 mm) long with screws 12” (305 mm) o.c. Three layers of 5/8” (15.9 mm) ToughRock® Fireguard C® gypsum board or 5/8” (15.9 mm) DensArmor Plus® Fireguard C® gypsum panel, screw-attached to 1-5/8” (41 mm) steel studs located at each corner of W10 x 49 (metric W250 x 73) column. spaced 1-1/2” (38 mm) from vertical edges. assemblies. 3. with 1” (25 mm) Type S screws 24” (610 mm) o.c. at intermediate studs. Face layer attached with 2-3/8” (60 mm) 6d cement coated nails 8” (203 mm) o.c. End joints located midway between joists and all joints offset 24” (610 mm) from base layer joints. ), 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied to one side of a double row of 2-1/2” (64 mm) 25- gauge (18 mils) steel studs 24” (610 mm) o.c. 2.5m : 21.2 kW/m2 . with 1-7/8” (48 mm) 6d coated nails 7” (178 mm) o.c. End joints attached with screws 8” (203 mm) o.c. Joints staggered. Joints staggered. Face Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C® applied horizontally to each side with 2-5/8” (67 mm) Type S drywall screws 12” (305 mm) o.c. End joints located midway between joists and staggered between rows. Non-Load Bearing. Gypsum panels end joints located over continuous channels and attached to additional pieces of channel 54” (1372 mm) long located midway between continuous channels at end joints. Helpful instructions and resources to help you locate assemblies, designs and related information. Stagger vertical joints 24″ (610mm) o.c. Stagger joints between layers and on base layer of both sides. Studs to be cut 3/4 in less than the assembly height CALIFORNIA EXPANDED METAL PRODUCTS CO — Viper25™ MARINO/WARE, DIV OF WARE INDUSTRIES INC — Viper25™ 2C. 1. to each side of 2” x 4” wood studs 16” (406 mm) o.c. Base layer attached with 1” (25 mm) Type S bugle head screws 16” (406 mm) o.c. Exterior Side: 5/8” (15.9 mm) DensGlass® Fireguard® Sheathing applied vertically or horizontally to 2”x 4” wood studs 24” (610 mm) o.c. Providing a product to “seal-up” these openings is a natural fit. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically to each side with drywall adhesive or secured with 1-5/8” (41 mm) Type S screws 12” (305 mm) o.c. 35 kW/m2) R-value of tested assembly . Recognize important nuances in the Middle Layer: 5/8” (15.9 mm) ToughRock Fireguard C gypsum board or 5/8” (15.9 mm) DensArmor Plus Fireguard C gypsum panels applied perpendicular to resilient channels with 1” (25.4 mm) Type S drywall screws 8” (203.2 mm) o.c. h�T�[K�0��O�G}д�� with 21-gauge (37 mils) galvanized steel hanger straps fastened to sides of joists. 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. at joints and top and bottom plates and 3/8”(10 mm) beads of adhesive at intermediate studs. Interior: Two layers 5/8” (15.9 mm) DensArmor Plus® Fireguard® or 5/8” (15.9 mm) ToughRock® Fireguard X® Products applied vertically to framing. Studs attached to floor and ceiling tracks with 1/2 in. Insulation to completely fill stud cavity. Wood joists supporting 1” (25 mm) nominal T&G wood subfloor and 1” (25.4 mm) nominal wood finish floor, or 19/32” (15.1 mm) plywood finished floor with long edges T&G and 15/32” (11.9 mm) interior plywood with exterior glue subfloor perpendicular to joists with joints staggered. 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied perpendicular to resilient channels 24 o.c. with 1” (25 mm) Type S drywall screws 12” (305 mm) o.c. 44 S641:2017 Standard For Factory-built Chimney Connectors And Wall Pass-through Assemblies - Third Edition 2017 ULC 45 S717.1-2017 Standard For Flat Wall Insulating Concrete Form (Icf) Units _ Material Properties - Second Edition 2017 ULC Sount tested wiht 1-1/2″ Fiberglass sound insulation. with 5d nails 1-5/8” (41 mm) long, 0.099” (2.5 mm) shank, 1/4” (6 mm) heads, 6” (152 mm) o.c. Face layer attached with 2-3/8” (60 mm) galvanized roofing nails 8” (203 mm) o.c. Studs attached to each side of the floor and ceiling runners by welding or with 1/2” (12.7 mm) Type S-12 panhead screws. ALL UL STDS for CANADA. Vertical joints midway between studs. with 1” (25 mm) Type S drywall screws 24” (610 mm) o.c. Base Layer: 1/2” (12.7 mm) ToughRock® Fireguard C® gypsum board or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied vertically to each side of 1-5/8” (41 mm) metal studs 24” (610 mm) o.c. 3) UL Edition Date: April 24, 2018 Type: ulstd. Upper channels secured to steel deck units with 1/2” (12.7 mm) Type S pan-head screws spaced 12” (305 mm) o.c. Step-by-step instructions on locating through penetration firestop system certifications. One layer of 5/8″ (15.9 mm) ToughRock® Fireguard X® Products or 2/8″ (15.9 mm) DensArmor Plus® Fireguard® gypsum panels installed vertically on each side with 1″ Type S screws 12″ o.c. Assembly Tests ANSI/UL10C-09 or ANSI/NFPA 252-2008 CAN/ULC-S104-10 Fire Door Frame and Transom Frame Design UL Subject 63-03 CAN/ULC-S105-09 Fire Window Assembly Tests ANSI/UL9-09 or ANSI/NFPA 257-2007 CAN/ULC-S106-15 Fire Door and Window Assembly Installation ANSI/NFPA 80-2010 ANSI/NFPA 80-2007 Optional glass fiber or mineral fiber batt or loose fill insulation applied directly gypsum board. BASALITE CONCRETE PRODUCTS VANCOUVER ULC EXPOCRETE CONCRETE PRODUCTS LTD GROUPE PERMACON, DIV OF OLDCASTLE BUILDING PRODUCTS CANADA INC Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54” (1372 mm) long with screws 12” (305 mm) o.c. Please consult the actual fire resistance directory or test report for complete information, and in no event shall the information herein be used for construction. Mounting Angles (Not Shown) - Min 3 in. CAN/ULC-S134-92 – Fire Test of Exterior Wall Assemblies . This manual provides the structure and set up of the administration of the standards development process at ULC Standards and provides the structure and procedures for the standards development process of ULC Standards Technical Committees. 2Tested with double 2x4 wood studs 16” OC, a 3” air gap, and 3-1/2” batt insulation on both sides. Angl es to be formed of min 1/8 in. attached horizontally on one side of 2” x 4” wood studs 24” o.c. Proprietary polymer modified exterior insulation and finish system applied over sheathing. Sound Tested with 3-1/2” (89 mm) fiberglass insulation. 2” (51 mm) maximum foam-on-plastic thickness. at edges and 12” (305 mm) o.c. with 1” (25 mm) Type S drywall screws 48” (1220 mm) o.c. Review and evaluate numerous wall assemblies constructed with a variety of Green Glue products in various combinations. 19 SWG galvanized hexagonal wire mesh. 4” (102 mm) maximum foam-on-plastic thickness. Third Layer: Attached to sheet-metal angles with 1” (25 mm) long, self-drilling, self-tapping screws spaced vertically 12” (305 mm) o.c. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Wood joists supporting 19/32” (15.1 mm) plywood and 1” (25 mm) proprietary sanded gypsum underlayment. perimeter caulked—UL Des U415 or U492, ULC W508—SA-910913 47 STC* and *** 2-hr. assemblies. Nails placed 3/4” (19 mm) from board end joints and 1/2” (12.7 mm) from board end joints. The SUIS covers manufactured articles neither regulated by OSHA Hazard Communication Standard, 29 CFR … PDF. ASTM E119 or CAN/ULC-S101 standard tests were used to rate . CAN/UL. One layer of 1″ x 24″ DensGlass Shaftliner or ToughRock Shaftliner inserted between 2-1/2″ floor and ceiling runners of minimum 2-1/2″ C-T, C-H or I studs between panels. at edges and ends and 8” (203 mm) o.c. Face Layer: 1/2” (12.7 mm) ToughRock Fireguard C or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied vertically to each side with 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. Stagger horizontal joints 24″ (610 mm) o.c. Designed to separate a room from structure or space above and composed of 1” (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel supported by 2-1/2” (64 mm), 4” (102 mm) or 6” (152 mm) C-T studs and three layers of 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panel. with vertical joints located mid way between studs. Base Layer: 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied vertically to each side of 1-5/8” (41 mm) steel studs 24” (610 mm) o.c. for face layer. Joints staggered. Face layer attached with 1-5/8” (41 mm) Type S-12 corrosion resistant bugle head screws spaced 8” (203 mm) o.c. Stagger joints 24” (610 mm) opposite side. at top and bottom track, 16” (406 mm) o.c. 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically (per ULC W301) or horizontally (UL U305) to each side of 2” x 4” wood studs 16” (406 mm) o.c. Fire-resistance rated assemblies. Horizontal bracing required at mid height. Outside corners of gypsum board protected by steel corner beads crimped or nailed to the gypsum board. Face Layer: 2”x 4” x 8” (51 x 102 x 203 mm) clay brick with 1” (25.4 mm) air space between brick and exterior sheathing. vertically. Resilient channels 24” (610 mm) o.c. with 1” (25 mm) Type S screws 16” (406 mm) o.c. and covered with a single layer fire resistant protective weather retarder paper stapled along each edge at 16” (406 mm) o.c. Furring channels attached with 18-gauge (43 mils) wire ties to open web steel joists 24” (610 mm) o.c. at end joints and 12″ (305mm) at perimeter adn intermediate studs. Face layer attached to base layer only with 1-1/2” (38 mm) Type G drywall screws 12” (305 mm) o.c. 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically to each side of 3-5/8” (92 mm) steel studs 24” (610 mm) o.c. on separate plates 1” (25 mm) apart with 1-7/8” (48 mm) 6d coated nails 7” (178 mm) o.c. with 1-1/4” (32 mm) drywall screws. One layer 1″ x 24″ (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel inserted between 2-1/2″ floor and ceiling J runners with H section of 2-1/2″ (64 mm), C-T, or C-H studs between panels. 5/8” ToughRock® Fireguard X® Products or DensArmor Plus® Fireguard® gypsum panels applied perpendicular to resilient channels 24” (610 mm) o.c.
Mark Teixeira Stats, Lizzie Rampage Human Form, Denver Pizza Company, Electric Winch For Sale In Pakistan, Restaurant Biltstraat Utrecht, Nova Scotia Election Candidates, Oxtongue River Fishing, University Of Kansas Track And Field Recruiting Standards, Texas Vs Alabama 2021,
Mark Teixeira Stats, Lizzie Rampage Human Form, Denver Pizza Company, Electric Winch For Sale In Pakistan, Restaurant Biltstraat Utrecht, Nova Scotia Election Candidates, Oxtongue River Fishing, University Of Kansas Track And Field Recruiting Standards, Texas Vs Alabama 2021,